Smartsight s1000 manual


















Length of Power Cord: 3'10". Product Dimensions:. Elongated: Round: Product Weight:. Round: 10 lbs. Seat Hole Dimensions:. Elongated: 7. Round: 7. Seat Thickness: 1. Color: White. SBWE Elongated. SBWR Round. Measure the distance between the toilet bolt holes. Measure the distance from the center of the toilet bolt holes to the toilet tank. Measure the distance from the toilet bolt holes to the from of the toilet bowl to see if you have a round or elongated toilet. Measure Your Toilet Before Purchasing Please carefully follow the measurement instructions to see if the SmartBidet model of your choice will fit your toilet before making your purchase.

If you are still unsure, please contact our Customer Support Team with the brand and exact model number of your toilet. How to Clean Use baking soda mixed with vinegar. Cleaning with strong detergents may lead to the deterioration of the plastic.

User Manual with Installation. Add to Cart. Choose the right shape for your toilet. Wireless Remote Control A remote control that fits within the palm of your hand.

Posterior Wash. Feminine Wash. Heated Dryer. DIY Easy Installation. Heated Water. Heated Seat. The firmware has started, but the unit is not 3 intervals connected to the network. Flashing green 0. Flashing green-red 1 sec.

Flashing red 0. The unit is being identified. In the worst case, it could flash at 5 Hz. Flashing red 1 sec. Flashing green 3 sec. The firmware has started, but the unit is not intervals connected to the network. Flashing green 1 sec.

Each one is bicolor green-red. Condition Indication 3 red blinks every 2 seconds No video source is detected and no video is transmitted. Steady green A video source is connected to the corresponding input but video is not transmitted. No video source is detected but video is transmitted. The CLI is hierarchically organized, with menus, sub-menus, and individual options representing configuration parameters.

Only the parameters that you are likely to change are described. A Command Prompt window appears. The CLI has a timeout that is triggered after three minutes of inactivity. Depending on the changed settings, the unit may perform a soft boot. For more information about the serial port settings of the specific product with which you want to interface, refer to its user manual or contact your product manufacturer.

You have access to two independent serial ports. Possible values range from bps to , bps for a transmitter or to , bps for a receiver. It may also not have parity check; most communication devices do not use parity. User Accounts The User Accounts menu enables you to protect the configuration of the unit by restricting its access with a user name and a password.

By default, this type of update is allowed. Be aware that this type of firmware update is the only one available for the Se and Se units. For more information about firmware updates, refer to the SConfigurator User Manual.

To improve the security of your system, you may prohibit such an access. If you activate the global security profile, the unit will only accept secure SSL connections.

It also means that you cannot access the unit anymore with Telnet and you cannot perform firmware updates through the IP network on it. This passkey must be the same for all units and the software tools to allow proper secure communication between them. It is recommended to perform this operation in SConfigurator version 2. Otherwise, to build a truly secure system, you should first access the CLI through a physical serial port connection, not through Telnet, therefore avoiding eavesdropping on the network.

A transmitter and a receiver connected together need to be running the same firmware version. For more information about these settings, contact your network administrator. DHCP Configuration DHCP dynamic host configuration protocol allows devices and computers connected to a network to automatically get a valid network configuration from a server. The IP address format is a bit numeric address written as four numbers separated by periods. Each number is in the range.

Each device on a network must have a unique IP address. Subnet Mask The subnet mask is the binary configuration specifying in which subnet the IP address of the unit belongs. A subnet is a portion of a network that shares a common address component. Unless otherwise specified by your network administrator, it is recommended to use a subnet mask of Warning Never use the IP address of the unit as the gateway value.

Ping Request Ping is a basic Internet program that allows you to check that a particular IP address exists and can accept requests. Advanced Menu The Advanced menu holds a series of advanced setups mainly used by SmartSight technical support. Some of these configuration parameters are available through the SConfigurator utility software. To identify an Se unit: 1 From the main menu, choose Advanced, then press Enter.

Re-enter i to set the LED to its original state. Load Default Configuration The Load Default Configuration command, located in the main menu, resets all unit parameters to their factory settings described in Appendix A, page To reset the parameters to their factory defaults with a hardware operation instead, see page Reboot System The Reboot System command, located in the main menu, performs a soft boot on the Se.

A system reboot clears all unsaved changes in the CLI and returns to your preset configuration. When a connection is created between two units, a message like the following is displayed: Video [ This information is displayed during 45 seconds.

For example: Se ver: 2. The unit requires this configuration prior to starting its functions. If no configuration is found, it tries to contact a DHCP server. If DHCP configuration fails—if the unit does not find a server or if it cannot get a configuration from it within one minute—the unit assigns itself temporary network settings based on the APIPA service. A unit in APIPA mode does not reside on the same subnet as the other devices on the IP network; therefore, it may not be able to see them or be visible to them.

You can either launch SConfigurator directly from the CD or copy the executable file first on your hard disk. The SmartSight Console window appears. The CLI main menu appears. Clicking it does not free the RS connection and does not save your settings.

You can use it to access the CLI command line interface of your unit. You need to disable any program using this port prior to starting this procedure. Turn off the Scroll Lock key on your keyboard before entering HyperTerminal. The Connection Description window appears. A Properties window appears. You can now use the CLI to configure your Se unit. Access points are mainly used with wireless transmitter units to transfer wireless content onto the wired IP network.

Also known as AutoIP. Bridge A unit linking a wireless network to a wired Ethernet network. The newest SmartSight bridge is the S CCTV Closed Circuit Television A television system in which signals are not publicly distributed; cameras are connected to television monitors in a limited area such as a store, an office building, or on a college campus.

CCTV is commonly used in surveillance systems. Each flavor corresponds to a specific number of lines and columns per video frame. SmartSight units and modems are DCE. Decoder See Receiver. Computers, switches, multiplexers, cameras, and keyboards are DTE.

The DVR takes the feed from a camera and records it into a digital format on a storage device which is most commonly the hard drive. Encoder See Transmitter. Ethernet A local-area network LAN architecture using a bus or star topology and supporting data transfer rates of 10 Mbps.

It is one of the most widely implemented LAN standards. A newer version of Ethernet, called Base-T or fast Ethernet , supports data transfer rates of Mbps. The A LAN can connect workstations, personal computers, and surveillance equipment like video servers. See also WAN.

Master An S unit controlling Sw transmitter stations and slave S units. MPEG-4 extends these earlier algorithms with synthesis of speech and video, fractal compression, computer visualization, and artificial intelligence-based image processing techniques.

Multicast Communication between a single sender and multiple receivers on a network; the devices can be located accross multiple subnets, but not through the Internet. This graphical product is used in conjunction with Ethernet and wireless video servers. Compare with PAL. Outdoor Wireless Bridge See Bridge. Compare with NTSC. PTL Push-to-Listen In a two-way system, the communication mode in which the listener must push a button while listening. PTT Push-to-Talk In a two-way system, the communication mode in which the talker must push a button while talking.

PTZ Camera Pan-Tilt-Zoom An electronic camera that can be rotated left, right, up, or down as well as zoomed in to get a magnified view of an object or area. A PTZ camera monitors a larger area than a fixed camera. Receiver A device converting a digital video signal into an analog form. Also called decoder. Repeater A range extender for wireless links. The SmartSight repeater is made up of two S bridges a master and a slave. RF Radio Frequency Any frequency within the electromagnetic spectrum associated with radio wave propagation.

When a modulated signal is supplied to an antenna, an electromagnetic field is created that is able to propagate through space. Many wireless technologies are based on RF field propagation.

S Series The SmartSight series of secure outdoor wireless video systems. The series includes the S unit for the 2. Sw The SmartSight outdoor wireless video transmitter operating on the 2. Se Series The SmartSight series of Ethernet video servers receiver and transmitter designed for video monitoring and surveillance over IP networks.

Se The SmartSight high-resolution Ethernet video server receiver and transmitter providing point-to-point analog extension with Web access. S The outdoor, wireless, digital SmartSight video bridging unit.

SConfigurator SmartSight Configurator A proprietary graphical program used to configure and update the firmware of video server and outdoor wireless bridge units.

Serial Port An interface that can be used for serial communication, in which only one bit is transmitted at a time. A serial port is a general-purpose interface that can be used for almost any type of device. Slave An S unit controlled by a master unit, typically in a repeater application.

SMI SmartSight Management Interface A proprietary graphical program used to access the command line interface of the S series units and to perform firmware updates.

Station bridge. Transmitter A device sending video signals captured with a connected camera or dome to a receiver. The transmitter converts the analog signal into a digital form before transmitting it.

Also called encoder. Video Server A unit transmitting or receiving video signals. It is designed to afford wireless networks the same level of protection as a comparable wired network. Wireless Cell A group of wireless devices that communicate together on the same radio frequency channel. Also called wireless LAN. Wireless Transmission A technology in which electronic devices send information to receivers using radio waves rather than wiring.

See IP address.